Product Configuration
- A Approval: Non-hazardous area
- B Output; Operating: 4-20mA HART; inside + LCD
- T Housing; Cover Sealing; Cable Entry: T17 316L hyg. IP66/68 NEMA6P;EPDM;NPT1/2 thread, T17 = side cover, hygiene
- 1S Sensor Range; Sensor Overload Limit: 40bar/4MPa/600psi gauge; 160bar/16MPa/2400psi
- 6 Calibration; Unit: Sensor range; psi
- 1 Membrane Material: 316L
- TD Process Connection: Tri-Clamp ISO2852 DN51 (2"), 316L, EHEDG, 3A
- D Transmitter Mounting; Fill Fluid: Direct; Vegetable oil
- A Additional Option 1: Not selected
- A Additional Option 2: Not selected
Product Highlights
- Large variety of different process connections and membrane materials
- New TempC Membrane minimizes influences of ambient and process temperature fluctuations
- HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
- Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
- Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
- Cost savings with modular concept for easy replacement of sensor, display or electronics
- Overload-resistant and function-monitored from the measuring cell to the electronics