Product Configuration
- AA Approval: Non-hazardous area
- 2 Output: 4-20mA HART
- 1 Display, Operation: LCD, push button on display/electronics
- R Housing: F15 stainless steel hygiene, glass window
- D Electrical Connection: Thread NPT1/2, IP66/68 NEMA4X/6P
- 1P Sensor Range: 10bar/1MPa/150psi gauge, 100mH2O/333ftH2O/4000inH2O overload: 40bar/4MPa/600psi
- G Reference Accuracy: Standard
- F Calibration; Unit: Sensor range; psi
- TJJ Process Connection: Tri-Clamp ISO2852 DN38 (1-1/2"), 316L, DIN32676 DN40, EHEDG, 3A, ASME-BPE
- A Membrane Material: 316L
- 4 Fill Fluid: Vegetable oil, FDA
- A Diaphragm Seal Connection: Direct
Product Highlights
- Large variety of different process connections and membrane materials
- New TempC Membrane minimizes influences of ambient and process temperature fluctuations
- Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
- For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
- Modular concept for easy replacement of display or electronics
- Seamless and independent system integration (HART/PA/FF)