Product Configuration
- 7 Approval: ATEX II 3G Ex nA II T6
- A Output; Operating: 4-20mA HART; extern + LCD
- C Housing; Cover Sealing; Cable Entry: T14 Alu IP66/67 NEMA6P; EPDM; NPT1/2 thread, T14 = side cover
- 1F Sensor Range; Sensor Overload Limit: 400mbar/40kPa/6psi gauge; 8bar/800kPa/116psi
- 4 Calibration; Unit: Sensor range; inH2O/ftH2O
- AG Process Connection: NPS 3" Cl.150 RF, 316/316L, flush mount flange ASME B16.5
- B Seal: EPDM
- A Additional Option 1: Not selected
- A Additional Option 2: Not selected
Product Highlights
- Best fit for vacuum applications and applications with corrosive and abrasive media
- Process safety through membrane breakage detection
- Overload-resistant high purity ceramic sensor (99.9% Al2O3)
- HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
- Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
- Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
- Cost savings with modular concept for easy replacement of sensor, display or electronics
No Data Available